Mostrar registro simples

dc.contributor.authorCollares, Fabrício Mezzomo
dc.contributor.authorLeitune, Vicente Castelo branco
dc.contributor.authorOgliari, Fabrício Aulo
dc.contributor.authorPiva, Evandro
dc.contributor.authorFontanella, Vania Regina Camargo
dc.contributor.authorSamuel, Susana Maria Werner
dc.date.accessioned2013-11-19T13:13:57Z
dc.date.available2013-11-19T13:13:57Z
dc.date.issued2009-07-09
dc.identifier.citationCOLLARES, Fabrício M ; LEITUNE, V. C. B. ; OGLIARI, Fabrício Aulo ; PIVA, Evandro ; FONTANELLA, V. R. C. ; Samuel, S. M. W. . Influence of the composition of an experimental adhesive on conversion kinetics, flexural strength and radiodensity. Revista Odonto Ciência (PUCRS. Impresso), v. 24, p. 414-419, 2009.pt_BR
dc.identifier.issn0102-9460
dc.identifier.urihttps://guaiaca.ufpel.edu.br/handle/123456789/795
dc.description.abstractPurpose: To evaluate the effect of the addition of three radiopaque agents to an experimental adhesive on conversion kinetics, flexural strength and radiodensity. Methods: The model adhesive was formulated by mixing 50 wt% Bis-GMA, 25 wt% TEGDMA and 25 wt% HEMA. Barium sulfate, Titanium dioxide and Zirconium in 0.1, 0.2, 0.4, 0.8 and 1.6 wt% were added separately resulting in 15 experimental groups and 1 control group. The conversion kinetics of the model adhesive was evaluated using real time Fourier Transform Infrared Spectroscopy. The flexural tests were performed on 5 specimens (12 × 2 × 2 mm) for each group (total n = 80) in a universal testing machine. The radiodensity was evaluated by using an aluminum step-wedge and VistaScan phosphorous plates radiographs digital system with 0.6 s exposure and focal distance of 40 cm. Results: No statistical difference (P > 0.05) was found in flexural strength among all groups. The values of degree of conversion ranged from 45.51% e 62.46%. All groups showed higher values than 0.54 mm of aluminum for the evaluation of radiopacity. Conclusion: The addition of radiopaquing agents increased the adhesive radiodensity and did not affect its degree of conversion and flexural strength.pt_BR
dc.language.isoen_USpt_BR
dc.publisherediPUCRSpt_BR
dc.relation.ispartofseriesv.24;n.4
dc.subjectDental adhesivept_BR
dc.subjectRadiopaquept_BR
dc.subjectDegree of conversionpt_BR
dc.subjectFlexural strengthpt_BR
dc.titleInfluence of the composition of an experimental adhesive on conversion kinetics, flexural strength and radiodensitypt_BR
dc.title.alternativeInfluência da composição de um adesivo experimental na cinética de conversão, resistência à flexão e radiodensidadept_BR
dc.typearticlept_BR