dc.date.issued2008
dc.identifier.citationMORAES, Rafael Ratto de ; RIBEIRO, Daiane dos Santos ; KLUMB, Miriam Margarete ; Brandt W.C. ; CORRER SOBRINHO, Lourenço ; BUENO, M. . In vitro toothbrushing abrasion of dental resin composites: packable, microhybrid, nanohybrid and microfilled materials . Brazilian Oral Research, v. 22, p. 112-118, 2008.pt_BR
dc.identifier.issn1806-8324
dc.identifier.urihttps://guaiaca.ufpel.edu.br/handle/123456789/834
dc.description.abstractThis study evaluated weight loss and surface roughening after toothbrushing of different resin composites: one packable (Solitaire 2, Heraeus Kulzer), one microhybrid (Charisma, Heraeus Kulzer), one nanohybrid (Simile, Pentron) and one microfilled (Durafill VS, Heraeus Kulzer). Cylindrical specimens (n = 20) were prepared. Half of the samples were submitted to 60,000 strokes, at 4 Hz, with a dentifrice-water slurry. Control samples (n = 10) remained stored at 37°C. Pre- and post-abrasion parameters for weight (mg) and surface roughness (Ra,μm) were determined on an analytical balance and a surface profilometer. Data were separately submitted to Repeated Measures ANOVA and Tukey’s test (α = 0.05). Percentages of weight loss were analyzed by ANOVA and Tukey’s test (α = 0.05). The relationship between both evaluations was assessed by Pearson’s test (α = 0.05). The means (%) for weight loss (standard deviation) were 0.65(0.2), 0.93(0.2), 1.25(0.6) and 1.25(0.4) for Simile, Durafill, Charisma and Solitaire, respectively. Baseline roughness means ranged from 0.065(0.01), 0.071(0.01), 0.066(0.02) and 0.074(0.01) for Simile, Durafill, Charisma and Solitaire, respectively, to 0.105(0.04), 0.117(0.03), 0.161(0.03) and 0.214(0.07) after testing. The composites with larger fillers presented higher weight loss and roughening than the finer materials (p < 0.05). For both evaluations, control specimens showed no significant alteration. No significant relationship between loss of weight and roughness alteration was detected (r = 0.322, p = 0.429)pt_BR
dc.language.isoen_USpt_BR
dc.publisherSociedade Brasileira de Pesquisa Odontológicapt_BR
dc.relation.ispartofseriesv.22, n.2;
dc.subjectComposite resinspt_BR
dc.subjectSurface propertiespt_BR
dc.subjectPhysical propertiespt_BR
dc.subjectToothbrushingpt_BR
dc.titleIn vitro toothbrushing abrasion of dental resin composites: packable, microhybrid, nanohybrid and microfilled materialspt_BR
dc.typearticlept_BR


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples