Mostrar registro simples

dc.contributor.authorLima, Fábio Garcia
dc.contributor.authorMoraes, Rafael Ratto de
dc.contributor.authorDel Pino, Francisco Augusto Burkert
dc.contributor.authorPowers, John Michel
dc.date.accessioned2013-11-29T13:48:57Z
dc.date.available2013-11-29T13:48:57Z
dc.date.issued2005
dc.identifier.citationLIMA, Fábio Garcia; MORAES, Rafael Ratto de; DEMARCO, Flávio Fernando; DEL PINO, Francisco Augusto Burkert ; POWERS, John. One-bottle adhesives: in vitro analysis of solvent volatilization and sealing ability. Brazilian Oral Research, São Paulo, v. 19, n.4, p. 278-283, 2005.pt_BR
dc.identifier.issn1806-8324
dc.identifier.urihttps://guaiaca.ufpel.edu.br/handle/123456789/843
dc.description.abstractThe aim of this study was to compare the solvent volatilization rate and evaluate the sealing ability of different one-bottle adhesives that were in constant clinical use – an ethanol/water-based adhesive (Single Bond, 3M/ESPE – SB) and an acetone-based adhesive (Prime & Bond 2.1, Dentsply/Caulk – PB). Nine bottles of each agent were collected from the clinics of a dental school, and new ones were used as controls. The weight of all bottles and of empty bottles was determined using an analytical balance. A drop of each solution was dispensed onto the balance, taking its initial weight(IW) and, after 10 min, its final weight(FW). The IW/FW ratio was used to determine the solvent’s volatilization rate. The bottles with the highest evaporation levels (SB Control and PB Control) and with the lowest evaporation levels (SB Test and PB Test) of each agent were applied in Class V restorations with margins in dentin. Specimens were thermocycled and immersed in a 0.5% basic fuchsin solution. Dye penetration was evaluated under magnification and the data were submitted to the Kruskal-Wallis test. Solvent volatilization was faster for the acetone-based adhesive. IW/FW ratios ranged from 1.239 to 1.515 for SB, and from 3.488 to 6.476 for PB. The PB-Control and SB-Control groups exhibited similar microleakage patterns. The highest dye penetration scores were found for the PB-Test group (p < 0.05). Results indicate that the sealing ability can be affected by the repeated opening of acetone-based adhesive bottles.pt_BR
dc.language.isoen_USpt_BR
dc.publisherSociedade Brasileira de Pesquisa Odontológicapt_BR
dc.relation.ispartofseriesv.19 n.4;
dc.subjectDentin-bonding agentspt_BR
dc.subjectDental leakagept_BR
dc.subjectSolventspt_BR
dc.subjectEvaporationpt_BR
dc.titleOne bottle adhesives in vitro analysis of solvent volatilization and sealing abilitypt_BR
dc.title.alternativeAdesivos de frasco único análise in vitro da volatilização do solvente e do selamento marginalpt_BR
dc.typearticlept_BR


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples